Appendix C Using Your PC-LPM-16 (Non-PnP) Board

PC-LPM-16/PnP User Manual

C-6

National Instruments Corporation

Base I/O Address Selection

The base I/O address for the PC-LPM-16 is determined by the switches
at position U26 (see Figure C-2). The switches are set at the factory for
the base I/O address hex 260. This factory setting is used as the default
base I/O address value by National Instruments software packages for
use with the PC-LPM-16. The PC-LPM-16 uses the base I/O address
space hex 260 through 26F with the factory setting. See Table C-2 for
the board factory settings.

Verify that this base I/O address space is not already used by other
equipment installed in your computer.

Note:

If any equipment in your computer already uses this base I/O address
space, you must change the base I/O address of the PC-LPM-16 or of the
other device.

If you change the PC-LPM-16 base I/O address, you must make a
corresponding change to any software packages you use with the
PC-LPM-16. For more information about the I/O address of your
computer, refer to your computer’s technical reference manual.

Table C-2.

PC Bus Interface Factory Settings

PC-LPM-16 Board

Default Settings

Hardware

Implementation

Base I/O Address

Hex 260

Interrupt Level

Interrupt level 5
selected
(factory setting)

W3:

Row 5

Analog Input

Bipolar input
selected (

±

5 V)

(factory setting)

W1:

B-C

W2:

B-C

U26

A9
A8
A7
A6
A5