Panasonic CS-A9CKPG User Manual
Page 54

CHECK THE DRAINAGE
•
Open front panel and remove air filters.
(Drainage checking can be carried out without removing the
front grille.)
•
Pour a glass of water into the drain tray-styrofoam.
•
Ensurethat water flows out from drain hoseof theindoor
unit.
EVALUATION OF THE PERFORMANCE
•
Operate the unit at cooling operation mode for fifteen
minutes or more.
•
Measure the temperature of the intake and discharge air.
•
Ensure the difference between the intake temperature and
thedischargeis morethan 8°C (46.4°F).
CHECK ITEMS
Is there any gas leakage at flare nut connections?
Has the heat insulation been carried out at flare nut
connection?
Is the connecting wire being fixed to terminal board firmly?
Is the connecting wire being clamped firmly?
Is thedrainageOK?
(Refer to “Check the drainage” section)
Is the earth wire connection properly done?
Is the indoor unit properly hooked to the installation plate?
Is the power supply voltage complied with rated value?
Is there any abnormal sound?
Is thecooling operation normal?
Is the thermostat operation normal?
Is theremotecontrol’s LCD operation normal?
Is the air purifying filter installed?
54
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G