Powerful mode operation – Panasonic CS-A9CKPG User Manual
Page 31

8.10. Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.
1. Cooling and Soft Dry Mode
•
When the Powerful Mode is set, the set temperature will be automatically decreased 3°C (37.4°F) against the present
setting temperature (Lower temperature: 16°C [60.8°F]). This operation automatically will be running under SHi Fan speed
(cooling), Lo- Fan Speed (Soft Dry).
•
Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.
In “Auto” setting, the vane will automatically swing up and down. However the upper and lower limit will be shifted 10°
downward.
2. Heating Mode
•
When the Powerful Mode is set, the set temperature will be automatically increased 3°C (37.4°F) against the present setting
temperature (Higher temperature: 30°C [86°F]).
•
The Fan Speed will shift as shown below:
•
Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 5° lower than previous setting.
In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.
3. Powerful mode will operate for 15 minutes only.
4. Powerful Mode will stop if:
•
Powerful mode button is pressed again.
•
Stopped by ON / OFF switch.
•
Timer-off activates.
•
Quiet mode button is pressed.
•
Operating mode is changed.
31
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G