Rs-232c interface, Introduction, Hardware specifications – Panasonic AJ-HD150FE User Manual
Page 108
– 108 –
RS-232C interface
1. Introduction
(1) The VTR can be operated by commands when the RS-232C interface is used.
(See command table on page 111 – 113.)
(2) Conditions for acknowledging commands from RS-232C interface
The front panel REMOTE/LOCAL switch must be at REMOTE.
The setup menu item No. 204 “RS232C SEL” must be ON.
If the above conditions are not met, [ACK] + [STX]ER001[EXT] is returned to the external unit.
Whether the [ACK] code is returned depends on the setting which has been selected for setup menu item No. 209
“RETURN ACK”.
2. Hardware specifications
External interface specifications
1) Connector specifications
Connector: D-SUB 25-pin (crossover cable supported)
Pin No.
Signal
Circuit name
Description
1
FG
Protective ground
Frame ground
2
RXD
Received data
Data is sent to PC.
3
TXD
Transmitted data
Data is received from PC.
4
CTS
Clear to send
Shorted with pin 5.
5
RTS
Request to send
Shorted with pin 4.
6
DTR
Data terminal ready
No processing
7
SG
Signal ground
Signal ground
20
DSR
Data set ready
+ voltage output after communication enable status
2) Example of connection with controller (PC)
■
Using crossover cable with D-SUB 25-pin
■
Using crossover cable with D-SUB 9-pin and
connectors
25-pin connectors
PC side
(D-SUB 25-pin
connector)
FG
TXD
RXD
RTS
CTS
DSR
SG
DTR
1
2
3
4
5
6
7
20
VTR side
FG
RXD
TXD
CTS
RTS
DTR
SG
DSR
1
2
3
4
5
6
7
20
PC side
(D-SUB 9-pin
connector)
RXD
TXD
DTR
SG
DSR
RTS
CTS
2
3
4
5
6
7
8
FG
RXD
TXD
CTS
RTS
DTR
SG
DSR
1
2
3
4
5
6
7
20
VTR side