1.2 General Specification Summary
PARAMETER
VALUE
Power Input
Voltage Range
80-160 VDC; 120 VDC nominal
Maximum Current
20 A
Typical Transient Current
+20A < 60ms; +10A < 600ms; -5A < 100ms
Typical Continuous Current
< 1A
Inputs and Outputs
Discrete Inputs
RUN and RESET commands
ON Voltage:
12 – 32 VDC,
+24 VDC nominal @ 6.5 mA
OFF Voltage:
1.0 VDC, maximum
Discrete Outputs
FAULT & OVERTEMP alarms
OFF Voltage:
32 VDC maximum @ 150 µA typical
Effective ON Resistance
1.1 kΏ, nominal
@ ≥ 1.5 VDC:
Analog Input
DEMAND command signal
Current: 4 to 20 mA; 25 mA Maximum
Voltage: 5 VDC Maximum
Internal Impedance: 200 Ώ
Analog Outputs
POSITION & MTR
CURRENT feedback
Current: 4 to 20 mA
External Load Resistance: 300 Ώ, Maximum
Maximum Common Mode Voltage
±200 VDC User I/O to 120 VDC Return (less serial interface)
Performance
All performance values are based on use with ACT2000 in default
configuration. Any changes to ACT2000 firmware settings to change stroke
profile will alter performance values.
Maximum Velocity
10 in/sec
Maximum Continuous Force
500 lbf (100% Duty Cycle)
Maximum Peak Force
1000 lbf (100% Duty Cycle)
Maximum Stroke
5.9 in (ACT2000-590P, configuration dependent)
2.0 in (ACT2000-200F, configuration dependent)
Accuracy
± 1% Full Stroke
Mean Time Before Unscheduled Removal
30,000 Hours
Life Cycles
32,000 Minimum
Environmental
Temperature, Operating Ambient:
-40
° C (-40° F) to +93° C (+200° F)
Temperature, Storage
-40
° C (-40° F) to +125° C (+257° F)
Environmental Rating
Rated to CSA Type 3 and European IP65
Sealed against dust, protected against water
EMC
Meets EN 50081-2 and EN50082-2 for DC powered industrial equipment
Vibration
Meets Mil-Std-810E, Category 4 (5 – 2000 Hz)
INSTALLING THE ACT2000