Figure 1-5: act2000 system power wiring diagram, Figure 1-7. typical power connection with battery – Hamilton Sundstrand Company ACT2000 User Manual
Page 18
12
ACT2000 USER GUIDE
Figure 1-5: ACT2000 System Power Wiring Diagram
+
_
PWR (RED)
PWR AUX (WHT/RED)
PWR RTN (GRN)
PWR AUX RTN (WHT/GRN)
ACT2000 120 VDC INPUT
POWER SUPPLY
120 VDC
FUSE
50,000 µF
Figure 1-6. Typical Power Connection With Power Supply
Figure 1-7. Typical Power Connection With Battery
WARNING - Shock Hazard
Connect both the 120 VDC power and auxiliary wires. If only the
primary power wires are connected, the 120 VDC auxiliary power
wires are electrically live and must be insulated on the ends.