beautypg.com

Hamilton Sundstrand Company ACT2000 User Manual

Page 51

background image

PARAMETER

DESCRIPTION

FACTORY

SETTING

Part Number

Describes part number of actuator model

Per Drawing

Actuator Type

Describes type of actuator

Stand Alone

Command Source

Sets type of command signal

Analog

Home Controls

the

direction the actuator will

move, extending or retracting, to find the
mechanical stop (HOME)

Retract

Span

Sets the maximum stroke length,
measured from the HOME position

5.9 inches

(ACT2000-580P)

2.0 inches

(ACT2000-200F)

Stop Position

Sets the signal loss position, measured
from the HOME position

0.1 inches

Interpolation Table

Sets how Demand signal is interpolated
between defined points

Linear

Position Loop Constant

20

Current Loop PID Constants

Proportional

2.0

Integral

200

Derivative

0

Velocity Loop PID Constants

Proportional

40

Integral

10,000

Derivative

0

Maximum Velocity

Sets the maximum velocity

6 in/s

Maximum Force

Sets the maximum force output

1000 lbf

Maximum Homing Velocity

Sets the maximum velocity used to find
the HOME position

0.5 in/s

Maximum Homing Force

Sets the maximum force the ACT2000 will
use to find the HOME position

500 lbf

Maximum Holding Force

Sets the maximum force to be used to
hold at the HOME position while the
position demand is < 4.1mA and > 2mA

500 lbf

Table 3-5. Typical ACT2000 Setup Parameters With Default Values

CH. 3: OPERATING THE ACT2000

45