Hamilton Sundstrand Company ACT2000 User Manual
Page 51
PARAMETER
DESCRIPTION
FACTORY
SETTING
Part Number
Describes part number of actuator model
Per Drawing
Actuator Type
Describes type of actuator
Stand Alone
Command Source
Sets type of command signal
Analog
Home Controls
the
direction the actuator will
move, extending or retracting, to find the
mechanical stop (HOME)
Retract
Span
Sets the maximum stroke length,
measured from the HOME position
5.9 inches
(ACT2000-580P)
2.0 inches
(ACT2000-200F)
Stop Position
Sets the signal loss position, measured
from the HOME position
0.1 inches
Interpolation Table
Sets how Demand signal is interpolated
between defined points
Linear
Position Loop Constant
20
Current Loop PID Constants
Proportional
2.0
Integral
200
Derivative
0
Velocity Loop PID Constants
Proportional
40
Integral
10,000
Derivative
0
Maximum Velocity
Sets the maximum velocity
6 in/s
Maximum Force
Sets the maximum force output
1000 lbf
Maximum Homing Velocity
Sets the maximum velocity used to find
the HOME position
0.5 in/s
Maximum Homing Force
Sets the maximum force the ACT2000 will
use to find the HOME position
500 lbf
Maximum Holding Force
Sets the maximum force to be used to
hold at the HOME position while the
position demand is < 4.1mA and > 2mA
500 lbf
Table 3-5. Typical ACT2000 Setup Parameters With Default Values
CH. 3: OPERATING THE ACT2000