3 mechanical installation, Dimensions, Mechanical installation – Hamilton Sundstrand Company ACT2000 User Manual
Page 10
4
ACT2000 USER GUIDE
Certifications
North American Certifications
CSA Class I, Div 1, Group B, C, D; T4
European Directive Compliance (CE Mark)
EEx d, IIB+H
2
; T4
94/9/EC Potentially Explosive Atmospheres (ATEX) 08 ATEX 6108 X
(replaces 02ATEX6050X)
98/37/EC Machinery Directive
89/336/EEC Electromagnetic Compatibility Directive (EMC)
Materials
Housing
6061-T6 Anodized Aluminum
Conduit Union
Zinc Plated Steel
Extension Rod
17-4 PH CRES
Clevis
17-4 PH CRES
Seals
Nitrile, RTV and Teflon
Rod End Bearings
Aluminum Bronze
Connectors
Aluminum
Dimensions
5.2 in x 6.5 in x 16.7 in (ACT2000-590P)
6.0 in x 10.0 in x 12.9 in (ACT2000-200F)
Weight
35 lbs (ACT2000-590P)
50 lbs (ACT2000-200F)
1.3 Mechanical Installation
This section describes proper ACT2000 installation. Ensure compliance
with the factory recommendations.
Dimensions
The ACT2000 can be mounted with any directional orientation, whether
horizontal, vertical, or at an angle. Figures 1-1 and 1-3 show external
dimensions and mounting provisions for the pin-mount version of the
ACT2000. Figures 1-2 and 1-4 show external dimensions and mounting
provisions for the flange-mount version. Ensure that additional swing
clearance is factored into mounting calculations, as required.
WARNING
Lifting Hazard – Do not attempt to hand-lift the actuator. Use
appropriate lifting equipment.