Check sheet (1/2) – Panasonic ASCT1F46E User Manual
Page 24
Product name:
Relay name:
Date:
Refer to the following
page and item on
Page / Category -
Section
Safety
□
Does the vehicle system have a fail-safe in case of a relay failure?
p1/1-1、p1/2-4
□
Has it been confirmed by testing under actual load, actual circuit, and
actual condition?
p2/4-1
□
Have load type, load current characteristic, and current value been
checked?
p2/4-2~4-9
□
Isn't the applied contact current too small ? (Small current is likely to
decrease the contact reliability.)
p2/4-10
□
Has connecting load polarity been checked?
p2/4-11
□
Is the load likely to cause instant voltage drop?
p2/4-12
□
Isn't the applied contact voltage too high? (High voltage decreases
electrical life.)
p3/4-13
□
Isn't applied coil voltage too high? (High voltage affects electrical life.)
p3/4-14
□
Isn't short pulse applied to coil?
p3/4-15
□
Isn't the switching frequency too high even including at abnormality?
p3/4-16
□
Doesn't switching continue for a long time?
p3/4-17
□
Does it switch under high temperature?
p3/4-18
□
Have precautions been checked for using of coil surge absorption
circuit?
p3/4-19
□
Have you checked there is no sneak current or voltage to the relay coil?
p3/4-20
□
Is there stray capacitance between lead wires?
p3/4-21
□
Have precautions been checked for using of contact protective circuit?
p4/4-22
□
Is there a risk of dead short in the power supply?
p5/4-23
□
Is there a risk of short circuit in the power supply at load rejection?
p5/4-23
□
Is there a risk of insulation and breakdown voltage between contacts in
each pole when high voltage is applied to a twin relay?
p5/4-24
□
Has hot start been considered?
p5/5-1
□
Is the ambient temperature within the range of use? Also, is the ambient
temperature characteristics considered?
p5/5-2
□
Is the applied voltage below the maximum continuous applied voltage?
p5/5-3
□
Is there a risk of using PWM control? (PWM control requires careful
attention.)
p5/5-3
□
Doesn't coil of twin relay operate at the same time?
p6/5-4
□
Hasn't the current continuously applied to coil over a long period?
p6/5-5
□
In case of relay operation by electric circuit, is the circuit designed in
consideration of mal-function?
p6/6-1、p8/6-2
□
Doesn't the surge voltage of relay cause mal-function or destruction of
transistor circuit?
p6/6-1、p8/6-2
□
When relay is applied to an electric circuit, has voltage drop caused by
other electric components on the circuit been considered?
p6/6-1、p8/6-2
Coil operation
circuit
Load/
Electrical life
Check item
Check
box
Category
Coil operation
voltage
Check sheet (1/2)