Using a Hot Spare Drive
If a third drive is attached and is not assigned to a mirrored two-drive disk array 
(one optimized for Security), it will be recognized as a spare drive. Such a drive 
is immediately used as a standby replacement. It is automatically added to an 
array once a disk member of the array has been detected as failed. 
To restore fault tolerance as quickly as possible, FastTrak TX4000 begins to 
perform an automatic data rebuild on the spare drive in the background without 
the need to restart the system. 
At a later time, the failed drive can be physically removed from the FastTrak 
TX4000 card and an extra drive added in its place to function as the spare drive. 
Important
The hot spare drive must have a capacity that is equal to or 
larger than the smallest array member. 
Creating Multiple Disk Arrays
If you plan to create multiple arrays,
1.
Attach only the drives necessary to create the first disk array and complete 
the Auto Setup (1). 
2.
Install the additional drives needed for the second array and again use the 
Auto Setup (1). 
Note
If you wish to customize the settings of individual disk 
arrays (such as block size), you must manually create disk 
arrays with the Define Array (3) option from the Main Menu. 