Perle PoE/PoE+ 10/100 Ethernet Media Converter
17
LKC- (Link Status on Copper port)
On – Copper link is present
Off – No copper link present
Blinking (fast) – Copper link up and receiving data
PSE
Solid Green (Active) – The PSE has successfully detected a compliant PD and is
applying power over UTP.
Solid Orange (Inactive) – The PSE is not active. The PSE has been configured to
provide power, however
•
a compliant PD not detected - no power applied
•
a PSE has turned off power for Reset function
Off – (Disabled) The PSE function is disabled in the configuration.
Error conditions
A blinking red light is an error condition. The led light will cycle with a 3 second
stop interval between the error condition code.
PSE-LED
1 blink
PD Capacitance too high
2 blinks
PD Resistance too low or short circuit
3 blinks
PD Resistance too high