Pd power reset (switch 6), Loopback fiber (switch 7) – Perle Systems S-110P User Manual
Page 10
Perle PoE/PoE+ 10/100 Ethernet Media Converter
10
detection
Down
Down
PSE disabled
These switches must be set in order to enable the power
sourcing function and to indicate the type of device detection
required. If the device type is unknown, the default should
be used as per IEEE802.3af/at standards.
Enabled: When enabled, the media converter will perform
Power Sourcing Equipment (PSE) functions as per
IEEE802.3af (POE) or 802.3at-2009 (POE+) standards.
Disabled: When disabled the media converter will not
perform PSE functions.
PD Power Reset (Switch 6)
Switch Position
Mode
Up (default)
Disabled
Down
Enabled
Disabled: When disabled, the loss of fiber link has no effect
on PSE power to the PD device.
Enabled: When enabled, if the media converter detects loss
of link on the fiber port it will turn off PSE output power to
the PD device connected to the copper port. After 2
seconds, the media converter will restore power to the PD
and the power will remain on until the fiber link transitions
from a link up to link down state.
Loopback Fiber (Switch 7)
Switch Position
Mode
Up (default)
Disabled
Down
Enabled