USER menu

(continued)

Item

Setting

Description

This sets the channel assignments for the controller’s analog
audio preset when editing the digital audio of the VTR using a

controller which does not have a digital audio edit preset

control function.
This selects the channel concerned when the VTR CUE edit
preset is set in compliance with the ON or OFF presetting for
the analog audio signals designated by the editor or
controller.
0: Not set.
1: Compliance with analog CH1 edit preset.
2: Compliance with analog CH2 edit preset.
3: Compliance with either analog CH1 ot CH2 edit preset.

This selects the connection method for the digital audio edit

IN point.
0: Cut processing
1: V Fade processing

This selects the connection method for the digital audio edit
OUT point.
0: Cut processing

1: V Fade processing

This selects the mode after cue-up operation is complete.
0: STOP mode

1: SHTL STILL mode

Superimposed

display

EDIT
RPLCEC

AUD EDIT

IN

AUD EDIT
OUT

AFTER
CUE-UP

Superimposed

display

N-DEF

CH1
CH2

CH1+2

No.

307*

No.

0000
0001
0002
0003

309*

CUT

FADE

CUT

FADE

STOP

STILL

0000
0001

0000
0001

0000

310*

313

0001

The underline on the setting item denotes the initial setting.

* The Setup menu can only be displayed for the model AJ-D650.

USER menu

Item

Setting

Description

This selects the time to be taken until the unit goes into the tape
protection mode when it is left standing in the stop mode.

(Unit: s = second, min = minute)


With the DV format, the maximum time which can be set is

10s even when a setting above 10s has been selected. The

selection screen, however, will operate for up to 2 minutes.

Superimposed

display

STILL
TIMER

No.

Superimposed

display

0000

0.5s

0001

5s

0002

10s

0003

20s

0004

30s

0005

40s

0006

50s

0007

1min

0008

2min

No.

400

401

SRC

PROTECT

0000

STEP

HALF

This selects the operation during the tape protection mode
when the unit is left standing in the still status in No. 400
protection mode.
0: STEP FWD.

1: HALF LOADING.


When STEP FWD is selected, the unit automatically goes into
the HALF LOADING mode when the total time for which the
unit is left standing in the still status reaches 30 minutes
(DVCPRO) or 1 minute (DV).

0001

The underline on the setting item denotes the initial setting.


In order to protect the tape and VTR helical heads, it is recommended that the Still Timer be
set for automatic tape protection mode in 30 seconds or under.