Chapter 7 menu description tables, 8-4 battery setting2 – Panasonic AJ- E User Manual
Page 101
7
Chapter 7 Menu description tables
101
Item/
Data storage
Variable
range
Remarks
Item/
Data storage
Variable
range
Remarks
7-8-4 BATTERY SETTING2
ENDURA80
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
: The selection is enabled.
/ : The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:
The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
13.6
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
NiCd14
2
/
11.0
:
13.6
:
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
: The selection is enabled.
/ : The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
:
13.2
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
NiCd13
2
/
11.0
:
12.7
:
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
: The selection is enabled.
/ : The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
:
12.2
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
NiCd12
2
/
11.0
:
11.5
:
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
: The selection is enabled.
/ : The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
:
11.2
:
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
BP-L60/90
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
: The selection is enabled.
/ : The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:
The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
:
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
NEAR END
END
NEAR END
END
NEAR END
END
The underlining in the variable range column indicates the setting in the preset mode.
C U F
C U F
C U F
C U F
C U F
HYTRON100, HYTRON120, DIONIC90, DIONIC160 or NP-
L50), the remaining battery charge displayed in the viewfinder
appears as a percentage.
What is displayed to warn the user that the end of the
remaining battery charge is approaching is determined by the
setting on the
the percentage display.