Powering up the dpoe ™ power patch panel – Panduit DPOE24S1X User Manual
Page 15

PANDUIT® DPoE™ Power Patch Panel User’s Guide
Issue 2.2
Part Number: PN378A
14
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WARNING:
The power supply connections are polarized. 
 
The DPoE™ Power Panel will not function if power is wired improperly. 
 
For Maximum power the overall length of the wire between the power 
supply and the DPoE™ Power Panel must not exceed 35 feet. 
NOTE:
The included power harness has two wires for the A-feed power only (pins 
1 & 2). The DPoE™ Power Patch Panel supports an optional redundant 
B-feed power option, but the terminals and wire leads are not attached to 
the power harness. 
 
Contact PANDUIT Technical Support for more information about 
connecting the redundant B-Feed Power. 
14. Lightly tug on the butt spliced connections to verify that the butt splices are secure.
Powering Up the DPoE™ Power Patch Panel
15. Plug the connector into the back of the DPoE™ Patch
Panel.
16. Once power is applied to the unit, the DPoE™ Power Patch
Panel will go through its power up sequence. The following 
table describes the behavior of the unit as viewed from the 
front and the back. 