4.7.9

Standing Pilot Toggle

For some applications, it is desirable to maintain the gas pilot flame when the appliance is
OFF. Heat from the pilot keeps the vat warmer for quicker start-ups in the morning. Default
setting for standing pilot is off.

Note: Heat Demand Profile (section 4.8.3) must be set to Generic 1, or T-stat.
Standing Pilot toggle has no effect in any other setting.

With display showing [MORE] [SERVICE], press key

. Display will show [STANDING]

[PILOT n], where “n” is ON or OFF. Use key

to toggle value, then press the

to

save choice. Display returns to [MORE] [SERVICE].

4.7.10 To Exit More Service Menu

With display showing [MORE] [SERVICE], press the

key. Display returns to [SERVICE].

Continue with Level 2 programming in section 4 (display showing [SERVICE]), or continue.

4.8

To Exit Programming Level 3

With display showing [SERVICE], press the

key. Display will show [PROGRAM]. Continue

with changes in section 2, or continue.

To return to normal operations, press the

key again. Display will show one of the normal

displays: [HEATING] or [READY].