Pitco Frialator Solstice I12 Water Cooker (Service Manual) User Manual
Page 17

Solstice I12 Water Cooker Computer Service
Part #60153301
L22-306 Rev 0
17
4.7.4
Shake Alarm Duration
With display showing [MORE] [SERVICE], press key
. Display will show [SH-DUR:nn]
[DURATION], where “nn” is the time in seconds the shake alarm will sound. Use location keys
for numeric entry of desired value, then press the
to save choice. Display returns to
[MORE] [SERVICE].
4.7.5
Hold Alarm Duration
With display showing [MORE] [SERVICE], press key
. Display will show [HD-DUR:nn]
[DURATION], where “nn” is the time in seconds the hold alarm will sound. Use location keys
for numeric entry of desired value, then press the
to save choice. Display returns to
[MORE] [SERVICE].
4.7.6
Cancel Duration
With display showing [MORE] [SERVICE], press key
. Display will show [CANCEL:nn]
[DELAY] , where “nn” is the time in seconds the operators must press a basket key to cancel a
cook. Use location keys for numeric entry of desired value, then press the
to save
choice. Display returns to [MORE] [SERVICE].
Default value is 4 seconds.
4.7.7
Configuration Value
With display showing [MORE] [SERVICE], press key
. Display will show [CFG hhhh],
where “hhhh” is a hexadecimal check sum of the program contained in the controller.
Modifications to any part of the setup of this control will change the check sum value. Press the
key. Display will return to [MORE] [SERVICE].
4.7.8
Factory Reset
Factory Reset provides a quick way to erase all setup changes and restore control to factory
settings.
Warning: Any settings made prior to a factory reset will be lost. This includes
customer specific downloads performed at Pitco Frialator.
With display showing [MORE] [SERVICE], press key
. After a few moments, the display
will show [ P ] for reset. Press the
display will return to [MORE] [SERVICE].