4.7.4

Shake Alarm Duration

With display showing [MORE] [SERVICE], press key

. Display will show [SH-DUR:nn]

[DURATION], where “nn” is the time in seconds the shake alarm will sound. Use location keys

for numeric entry of desired value, then press the

to save choice. Display returns to

[MORE] [SERVICE].

4.7.5

Hold Alarm Duration

With display showing [MORE] [SERVICE], press key

. Display will show [HD-DUR:nn]

[DURATION], where “nn” is the time in seconds the hold alarm will sound. Use location keys

for numeric entry of desired value, then press the

to save choice. Display returns to

[MORE] [SERVICE].

4.7.6

Cancel Duration

With display showing [MORE] [SERVICE], press key

. Display will show [CANCEL:nn]

[DELAY] , where “nn” is the time in seconds the operators must press a basket key to cancel a

cook. Use location keys for numeric entry of desired value, then press the

to save

choice. Display returns to [MORE] [SERVICE].

Default value is 4 seconds.

4.7.7

Configuration Value

With display showing [MORE] [SERVICE], press key

. Display will show [CFG hhhh],

where “hhhh” is a hexadecimal check sum of the program contained in the controller.
Modifications to any part of the setup of this control will change the check sum value. Press the

key. Display will return to [MORE] [SERVICE].

4.7.8

Factory Reset

Factory Reset provides a quick way to erase all setup changes and restore control to factory
settings.

Warning: Any settings made prior to a factory reset will be lost. This includes
customer specific downloads performed at Pitco Frialator.

With display showing [MORE] [SERVICE], press key

. After a few moments, the display

will show [ P ] for reset. Press the

display will return to [MORE] [SERVICE].