4.4.8

Fill Done Input:

Press the product key 8. Display will show state of the Fill Done input [FD xxx], where
xxx is ON or OFF. Product key 8 indicator shows the ON or OFF state of the input.

4.4.9

Exit Diagnostic Menu

To exit diagnostic menu, Press the

key. Display will return to [SERVICE]. Other service

menu items may be selected for changes.

To return to programming press the

key again. Display will show [PROGRAM]. Other

settings can be made in section 2.

To return to normal operations, press the

key again. Display will show one of the normal

displays: [HEATING] or [READY].

4.5

Ready Level

With display showing [SERVICE], press product key 6.

Display shows [READY nn], where “nn” is the value, in degrees below set temperature that
the READY message is displayed. To change this value, use the location keys for numeric
entry of a new value

. Factory default value is 10°F

.

Press the

key. Display now shows [SERVICE].

4.6

Temperature Operating Range

Forces the control to display the range of temperatures that may be set by operators.

With display showing [SERVICE], press product key 7.

Display shows [RANGE 1] [

150 230

]. No adjustments are permitted here. This is an

information display only. Press the

key. Display returns to [SERVICE].

4.7

More Service Menu Entry

With display showing [SERVICE], press product key 8.

Display now shows

.

Location keys will illuminate where adjustments are permitted; all other keys are inactive. The following
section details each product key function in the More Service Menu.

4.7.1

Cook Now

Should operators be forced to acknowledge a Cook Done Alarm before starting another cook?
This setting forces that requirement.

Factory default value is OFF

.