Communication setup communication setup, Serial port setup serial port setup, Protocol selection (protocol select) – Panasonic WJ-HD200 User Manual
Page 63: Baud rate (baud rate), Data bit (data bit), Parity check (parity check), Stop bit (stop bit), Wait time (wait time), Alarm data (alarm data)

64
8
Parity Check (PARITY CHECK)
NONE:
No parity check
EVEN:
Even parity
ODD:
Odd parity
8
Stop Bit (STOP BIT)
1 bit:
1 bit
2 bit:
2 bits
8
Wait Time (WAIT TIME)
OFF:
Retransmission is disabled.
100 MSEC:
100 m seconds
200 MSEC:
200 m seconds
1 SEC:
1 second
8
System Unit Address (SYSTEM UNIT ADDRESS)
(only for PS
•
DATA)
Assignable address:
From 1 to 99, must be unique in
the chain.
8
Control Unit Address
(CONTROL UNIT ADDRESS) (only for PS
•
DATA)
Assignable address:
From 1 to 99, must be unique in
the chain.
8
Alarm Data (ALARM DATA)
OFF:
Select this when no system controller is connect-
ed.
0 SEC:
Pauses no time.
1 SEC:
Pauses for 1 second.
5 SEC:
Pauses for 5 seconds.
Click the [SET] button if all are adequately set.
Click the [CAMERA NO. SETUP] button. The CAMERA NO.
SETUP window opens.
■
Communication Setup
COMMUNICATION SETUP
Click the [SERIAL SETUP], or [NETWORK SETUP] button.
The respective window opens.
■
Serial Port Setup
SERIAL PORT SETUP
8
Protocol Selection (PROTOCOL SELECT)
PS
•
DATA:
Select when the communication chain uses
the PS
•
DATA protocol.
When selected, the DATA terminal on the rear panel
can be used.
VCR:
Select when other than PS
•
DATA is used.
When selected, the RS-232C terminal on the rear
panel can be used.
8
Baud Rate (BAUD RATE)
4800:
4 800 bps
9600:
9 600 bps
19200:
19 200 bps
8
Data Bit (DATA BIT)
7:
7 bits
8:
8 bits; select 8 when using the VCR protocol.