B-11

OPERATION

B-11

MULTIPLE ARC AC ADJUSTMENTS FOR
SYSTEMS EQUIPPED WITH K2282-1
SYSTEM INTERFACE

Phase

The phase relationship between the arcs helps to
minimize the magnetic interaction between adjacent
arcs. It is essentially a time offset between the wave-
forms of different arcs, and is set in terms of an angle
from 0 to 360°, representing no offset to a full period
offset. The offset of each arc is set independently
with respect to the lead arc of the system (ARC 1).

Recommendations:

• For balanced waveforms a phase relationship of 90°

should be maintained between adjacent arcs.

ARC 1

ARC2

ARC3

ARC 4

2 Arc System

90°

X

X

3 Arc System

90°

180°

X

4 Arc System

90°

180°

270°

• For unbalanced waveforms:

– Avoid switching at same time
– Break up long periods of unchanged polarity

relative to adjacent arcs

POWER WAVE® AC/DC 1000

Phase Relationship

500

-500

0

Use Phase Relation ship to min imize arc blo w

in multip le arc systems.

(Balanced two arc syst em sh own)

(PULL)

90°

(PUSH/PULL )

180°

(PUSH)

BAD

GOOD

BAD

ARC 1

ARC 2

Best result s obtained by alternating and equalizing the dur ation of

magnetic for ces between adjacent arcs.