Switch

Description

1

Object Instance LSB* (see table A.14)

2

Object Instance MSB** (see table A.14)

3

Equipment Group 1 Select (default OFF)

4

Equipment Group 2 Select (default OFF)

5

Equipment Group 3 Select (default OFF)

6

Equipment Group 4 Select (default OFF)
Arclink Object Auto mapping enabled (default)
Arclink Object Auto mapping disabled
Work sense lead not connected
Work sense lead connected (default)

Comments

Arclink configuration

Default setting
Requires manual configuration
Used for configuring work
sense lead ( See section A )

Comments

ArcLink Configuration

Must be OFF for
Power Wave AC/DC 1000
Gear ratio configuration.

These two options available in
S25564-11 and later software.

Comments

Used for Arclink
Configuration

Comments

Used for DeviceNet
Configuration

CONTROL BOARD DIP SWITCH (S1):

FEED HEAD BOARD DIP SWITCH (S1):

ETHERNET BOARD DIP SWITCHES (S1, S2):

A-25

INSTALLATION

POWER WAVE® AC/DC 1000

A-25

7

8

1 2 3 4 5 6 7 8

O
N

{

OBJECT INSTANCE

(*DEFAULT SETTINGS SHOWN)

GROUP SELECT

AUTO MAP

WORK VOLTAGE
SENSE ENABLE

1 2 3 4 5 6 7 8

O
N

{

OBJECT INSTANCE

GROUP SELECT

ELECTRODE
POLARITY

SPEED RANGE

(*DEFAULT SETTINGS SHOWN)

1 2 3 4 5 6 7 8

O
N

{

{

OBJECT INSTANCE

GROUP SELECT

RESERVED

(*DEFAULT SETTINGS SHOWN)

1 2 3 4 5 6 7 8

O
N

{

BAUD RATE (125K)

DEVICENET MAC ID (62)

(*DEFAULT SETTINGS SHOWN)

*LSB - Least Significant Bit
**MSB - Most Significant Bit

Switch

Description

1

Object Instance LSB (see table A.14)

2

Object Instance MSB (see table A.14)

3

Equipment Group 1 Select (default OFF)

4

Equipment Group 2 Select (default OFF)

5

Equipment Group 3 Select (default OFF)

6

Equipment Group 4 Select (default OFF)
Electrode polarity positive (default)
Electrode polarity negative
Low speed gear 142:1 (default)
High speed gear 95:1
High speed gear 57:1
Reserved (presently configured for 57:1)

Switch

Description

1

Object Instance LSB (see table A.14)

2

Object Instance MSB (see table A.14)

3

Equipment Group 1 Select (default OFF)

4

Equipment Group 2 Select (default OFF)

5

Equipment Group 3 Select (default OFF)

6

Equipment Group 4 Select (default OFF)

7

Reserved for future use (default OFF)

8

Reserved for future use (default OFF)

Description

DeviceNet Baud Rate
see Table A.15

DeviceNet Mac ID
see Table A.16

Switch

1
2
3
4
5
6
7
8

7

8

off
on
off

1

on

1

off

2

on

2

off
on
off
on

TABLE A.10

TABLE A.11

TABLE A.12

TABLE A.13

BANK S1

BANK S1

Bank S1 – ArcLink Set-up

Bank S2 – DeviceNet Set-up

Notes:

1. No jumper installed on External I/O connector (pin 5 to pin 12).
2. Jumper installed on External I/O connector (pin 5 to pin 12).

}

This manual is related to the following products: