Installation – Lincoln Electric POWER WAVE 11124 User Manual
Page 32
A-22
INSTALLATION
POWER WAVE® AC/DC 1000
A-22
Table A.7 External I/O S7 (12 pin – terminal block)
PIN
Lead #
Function
1
851
+15vdc for Trigger group
2
852
Trigger input
3
853
Dual procedure input
4
854
4 step input (Disabled as of S25564-19)
5
855
+15vdc for cold inch group (Disabled as of S25564-19)
6
856
cold inch forward
7
857
cold inch reverse
8
858
gas purge input
9
859
+15vdc for shutdown group
10
860
shutdown1 input
11
861
shutdown2 input
12
862
input B
Table A.9 Ethernet Connector S9 (8 pin – RJ-45 Style Connector / cat 5 Cable)
PIN
Function
1
Transmit +
2
Transmit -
3
Receive +
4
---
5
---
6
Receive -
7
---
8
---
Table A.8 Master / Slave I/O and System Interface Output Receptacles (22 Pin – MS bayonet style)
Pin
Master / Slave Input
Master / Slave Output
Optional System Interface
(S12)
(S13)
(ARC1, ARC2, ARC3, ARC4)
A
Reserved for future use
Reserved for future use
---
B
Reserved for future use
Reserved for future use
---
C
Sync In
Reserved for future use
Sync Out
D
Sync In
Reserved for future use
Sync Out
E
Ready In
Ready In
---
F
Ready In
Ready In
---
G
Polarity Out
Polarity Out
---
H
Polarity Out
Polarity Out
---
I
Ground
---
---
J
Reserved for future use
Reserved for future use
---
K
Reserved for future use
Reserved for future use
---
L
+40v (COM)
Reserved for future use
---
M
+40v ("+")
Reserved for future use
---
N
Reserved for future use
Reserved for future use
---
P
Reserved for future use
Reserved for future use
---
R
Reserved for future use
Reserved for future use
---
S
Reserved for future use
Reserved for future use
---
T
Drain (ethernet)
Drain (ethernet)
---
U
Kill Out
Kill Out
---
V
Kill Out
Kill Out
---
W
Work voltage sensing (21)
Work voltage sensing (21)
---
X
Electrode Voltage Sensing (67)
Electrode Voltage Sensing (67)
---