Retest after repair, Troubleshooting and repair – Lincoln Electric BULLDOG SVM208-A User Manual
Page 97
TROUBLESHOOTING AND REPAIR
F-49
F-49
BULLDOG® 140
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics.
OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
No Load RPM
Load RPM
Maximum Speed
3800
3650
Minimum Speed
3700
3350
WELDER/GENERATOR OUTPUT
1
Output Control
Field Volts
Field Amps
Open Circuit
Load Volts
Load Amps
Volts
Maximum
37.5 - 42.5
4.25 - 6.5
60 - 66
23 - 30
136 - 150
Minimum
–
–
55 - 62
28 - 36
50 - 85
AUXILIARY POWER RECEPTACLE OUTPUT
1
230 Volt Receptacle
115 Volt Receptacle
2
Output
Open Circuit
Load Volts
Load Amps
Open Circuit
Load Volts
Load Amps
Control
Volts
Volts
Maximum
240 - 260
216 - 240
19.2 - 22
120 - 130
108 - 120
17 - 20
1
Current Control Dial set at MAXIMUM or GENERATOR.
2
Output values of each receptacle can vary within the range shown