OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

No auxiliary power - welding output
is normal - engine runs normally.

1. Check circuit breakers CB1 and

CB2. Reset if tripped.

2. Make sure that the control rheo-

stat (R1) is set at “GENERATOR”
(maximum).

3. Check for loose or faulty plug at

power receptacle.

1. Check the auxiliary power re -

ceptacles and associated wires
for loose or faulty connections.

2. Check the continuity (zero

ohms) of leads 3, 3A (black); 6,
6A (yellow); and 5 (white) from
the receptacles to the stator
windings. See the Wiring Dia -
gram.

3. Make sure lead 5 (white) is

grounded to the machine frame
(zero ohms).

4. Check for an open or grounded

auxiliary winding in the stator, 6
(yellow) to 3 (black). See the
Wiring Diagram.

TROUBLESHOOTING AND REPAIR

F-7

F-7

BULLDOG® 140

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC