Table b.1, Table b.1 , generator power applications, Operation – Lincoln Electric BULLDOG SVM208-A User Manual
Page 23
![background image](/manuals/165283/23/background.png)
OPERATION
B-7
B-7
BULLDOG® 140
TABLE B.1
GENERATOR POWER APPLICATIONS
Suggested Power Applications
Running Watts
*Start-up Watts
(Continuous) (Surge)
*Air Compressor - 1 HP
2,000
4,000 - 8,000
*Air Compressor - 3/4 HP
1,250
3,100 - 5,000
*Airless Sprayer - 1/3 HP
600
1,500 - 2,400
Chain Saw
1,200
Circular Saw
1,200
Coffee Maker
1,000
*Deep Freezer
500
750 - 2,000
*Electric Motor - 1 HP
1,000
2,500 - 4,000
Electric Range (1 element)
1,500
Electric Skillet
1,250
*Furnace Fan - 1/3 HP
1,200
3,000 - 4,800
Portable Grinder (4 1/2”)
600
Portable Grinder (7”)
2,000
Halogen Work Light
500
Hand Drill - 1/4”
500
Hand Drill - 3/8”
700
1500 Watt Heater
1,500
Hedge Trimmer
450
Light Bulb
100
Reciprocating Saw
900
Radial Arm Saw
2,600
Radio
50
*Refrigerator/Freezer (small)
600
1,500 - 2,400
Slow Cooker
200
*Submersible Pump - 1 HP
1,000
2,500 - 4,000
*Sump Pump
600
1,500 - 2,400
Toaster
1,100
Weed Trimmer
500
Lincoln Wire Feeder/Welder
4,000
NOTES:
Wattages listed are approximate. Check your equipment for actual wattage.
Equipment with unusually high *START-UP WATTS are listed. For start-up of other tabled equipment that uses a
motor, allow up to 2 times the running watts shown above. For example a 1 HP motor requires approximately 1000
watts of power when running but may require (2.5 X 1000) = 2500 watts or (4.0 X 1000) = 4000 watts to start.
Multiple loads can be used as long as the total load does not exceed 5,500 surge watts or 4,000 continuous watts.
Be certain to start the largest loads first.
Output rating in watts is equivalent to volt-amperes at unity power factor (resistive load) and is calculated as:
WATTS = VOLTS X AMPS DRAWN. for example a 120 volt device which is rated on its nameplate to draw 2
amps will need (120 VOLTS) X (2 AMPS) = 240 WATTS OF POWER. 1 KW = 1000 WATTS.