OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

No weld output - auxiliary power
(230 - 115 VAC) operates normally
- engine runs normally.

1. Check the open circuit voltage

(OCV) at the welder output termi-
nals. If OCV is okay, go to Step
2, below.

If OCV is not present at the welder
output terminals, contact your
local Lincoln Electric Authorized
Field Service Facility.

2. Check the welding cables,

clamps and electrode holder for
loose or broken connections.

1. Check continuity (zero ohms) of

lead W1A (black) from output
terminal to reactor (L1). See
the Wiring Diagram.

2. Check continuity (zero ohms) of

lead W2 (black) from output ter-
minal to stator winding. See the
Wiring Diagram.

3. Check continuity (zero ohms) of

lead W1 (black) from reactor
(L1) to stator winding. See the
Wiring Diagram.

4. Check reactor (L1) for continuity

of winding. See the Wiring Dia -
gram.

5. Check the stator for continuity

of winding. See the Wiring Dia -
gram.

6. Make certain the reactor and/or

stator are NOT grounded. Mini -
mum acceptable resistance to
ground is 500 K-ohms.

TROUBLESHOOTING AND REPAIR

F-6

F-6