EP-15 Fluid Level Calibration
The default calibration for the EP-15 Fluid Level is just as accurate as

standard fluid level gauges. If, however, the tank has an irregular

shape or greater accuracy is needed, calibration is recommended. There

are three calibration options: 2-Point, 3-Point and 5-Point.

2-Point Calibration

A 2-point calibration is best suited for rectangular or square-shaped

tanks, where the capacity of the top half of the tank matches the capac-

ity in the lower half of the tank. In a two-point calibration, you will set

two points, one each for empty and full levels.
You can begin calibration at either of the two points, but we recom-

mend starting with an empty tank. You will fill the tank to complete

calibration.
1. Press

MENU| MENU

, use

↓ ↑ to select

NMEA

2000

and press

ENT

.

2. Highlight

B

US

S

ETUP

and press

ENT

, which will open the Bus Configu-

ration menu. A list of network devices will be at the top of the page.
3. Select the EP-15 Fluid Level and press

ENT

.

4. Press

↓ to select

C

ALIBRATE

and press

ENT

. The Device Calibration

menu will appear. Instructions on Calibration will be listed at the top

of the menu.
5. Highlight

N

UM

P

TS

, press

ENT

and select 2. Press

ENT

.

6.

Select

F

LUID

L

EVEL

,

press

ENT,

then select

E

MPTY

L

EVEL

and press

ENT.

7. Make sure the fuel tank is empty, highlight

C

ALIBRATE

and press

ENT

.

The following message will appear: Empty Level Calibration Com-
pleted.

Press ENT.

8.

Fill up your tank, highlight

F

LUID

L

EVEL

and press

ENT.

9.

Select

F

ULL

L

EVEL

and press

ENT.

Highlight

C

ALIBRATE

and press

ENT.

10.

The following message will appear

:

Full level Calibration Com-

pleted.

Press

ENT

, then press

EXIT

repeatedly to get back to the main

display.