Installation & Operation Manual

Ratings

5

Notes:

1.

The ratings are based on standard test procedures
prescribed by the United States Department of Energy.

2.

Use only the vent materials and methods specified in the
Venting Section of the EnergyRite Installation and
Operation Manual.

3.

This appliance is equipped for operation up to 2000 feet,
and including up to 4000 feet, with no field adjustments.
The appliance output ratings up to 4000 feet shall be
reduced by 4% for each 1000 feet above sea level. For
operation above 4000 feet, consult the factory.

Model Number

Note: Change “N” to “L”

for Propane gas

models.

Add suffix “-A” for

ASME models.

Input

Btu/hr

Pool Heater Water Content

Gallons

Gas

Connections

Vent/Air Size

Maximum Working Pressure

(PSI)

(Note 3)

ASME

NON-ASME

(NPT)

Conventional

DirectAire

(Note 2)

E-Rite

(Note 2)

ASME

NON-ASME

ERN152

150,000

0.58

0.83

3/4"

5"

4"

4"

125

50

ERN202

199,999

0.58

0.84

3/4"

5"

4"

4"

125

50

ERN252

250,000

0.59

0.84

3/4"

6"

5"

5"

125

50

ERN302

300,000

0.59

0.85

3/4"

6"

5"

5"

125

50

ERN402

399,999

0.60

0.85

3/4"

6"

6"

6"

125

50