beautypg.com

Sidewall venting – Lochinvar EnergyRite ER302 User Manual

Page 28

background image

28

Installation & Operation Manual

5

Sidewall venting

TABLE - 5C

AIR SHUTTER ADJUSTMENT OPENING FOR

E-RITE VENT SYSTEMS

Model

Number

“A” Dimension

Opening

Chamber Pressure

ER152

1 1/4"

1.4"

ER202

1 1/4"

1.4"

ER252

1 3/8"

1.4"

ER302

1 9/16"

1.4"

ER402

1 3/4"

1.4"

"A"

Figure 5-6_Combustion Air Fan with Air Shutter “A”
Dimension

The E-Rite Sidewall Vent kit includes recommendations to
purchase and install specific sidewall vent terminations from
recommended AL29-4C vent system manufacturers. This
venting kit includes installation instructions, a flue adapter, air
pipe adapter, air inlet collar assembly, air inlet terminal, flexible
steel re-enforced air hose, clamps, gaskets, and fasteners
necessary to install the venting system.

TABLE - 5D

E-RITE SIDEWALL VENT KITS

Model

Number

Inlet & Outlet

Vent Diameter

E-Rite Sidewall

Vent Kit

ER152

4"

HDK3045

ER202

4"

HDK3045

ER252

5"

HDK3046

ER302

5"

HDK3047

ER402

6"

HDK3048

The connection from the vent to the sidewall cap must be made
with a listed AL29-4C stainless steel sealed vent system suitable
for venting direct vent applications. There shall be no reduction
in vent size from the pool heater’s flue outlet to the inlet of the
sidewall vent cap. Vent pipe material may be purchased locally
by the installer.

Recommended manufacturers of listed AL29-4C vent system
materials are identified as follows:

Protech Systems Inc., www.protechinfo.com

Z-Flex, www.Z-Flex.com

Heat-Fab Inc., www.heat-fab.com

Metal-Fab Inc., www.mtlfab.com