Server configuration, Figure 4-3. server settings – Lantronix UDS2100 User Manual
Page 25

4: Configuration Using Web Manager
UDS2100 User Guide
25
Server Configuration
The unit’s server values display when you select Server from the main menu. The
following sections describe the configurable parameters on the Server Settings page.
Figure 4-3. Server Settings
To configure the UDS2100’s device server settings:
1. On the main menu, click Server.
2. Configure or modify the following fields:
Server Configuration
Telnet Password
Enter the password required for Telnet access.
Retype Password
Re-enter the password required for Telnet access.
Advanced
ARP Cache Timeout
(secs)
When the unit communicates with another device on the
network, it adds an entry into its ARP table. ARP Cache
timeout defines the number of seconds (1-600) before it
refreshes this table.
TCP Keepalive (secs)
TCP Keepalive time defines how many seconds the unit
waits during network failure or network interruption
before checking its status. If the unit does not receive a
response, it drops that connection. Enter a value between
0 and 65 seconds. 0 disables keepalive. The default
setting is 45.