beautypg.com

Adjustment – Kenwood TK-270G User Manual

Page 34

background image

TK-260G/270G

34

• Preparations for tuning the transceiver

Before attempting to tune the transceiver, connect the unit

to a suitable power supply.

Whenever the transmitter is tuned, the unit must be

connected to a suitable dummy load (i.e. power meter).

The speaker output connector must be terminated with a

8

dummy load and connected to an AC voltmeter and an

audio distortion meter or a SINAD measurement meter at all
times during tuning.

• Transceiver tuning

(To place the transceiver in tuning mode)
Channel appears on the LCD. Set the channel according to

the tuning requirements.

ADJUSTMENT

Test Mode (TK-270G only)

Test mode operating features

This transceiver has a test mode. To enter test mode,

press the [

2

] key and turn the power on. Hold the [

2

] key

until the test channel No. and test signalling No. appear
on LCD.
Test mode can be inhibited by programming. To exit
test mode, switch the power on again. The following functions
are available in test mode.

• Controls

[PTT]

Used when making a transmission.

[MON]

Monitor ON and OFF.

[LAMP]

Changes wide and narrow.

[

°

]

Sets to the Tuning mode.

[

]

Unused

[

2

]

RF power HIGH and LOW.

[

3

]

Changes signalling.

[O] to [9],

Used as the DTMF keypad. If a key is pressed

and [#],[

]

during transmission, the DTMF corresponding

and [A] to [D] to the key that was pressed is sent.
[ENCODER] Changes channel.

• LCD indicator
“LO”

Lights at RF Power Low.

“ ”

Lights at moniter ON.

• LED indicator
Red LED

Lights during transmission. Blinks during low
battery voltage warning.

Green LED

Lights when there is a carrier.

Frequency and signalling
The set has been adjusted for the frequencies shown in the

following table. When required. re-adjust them following the
adjustment procedure to obtain the frequencies you want in
actual operation.

Frequency (MHz)

K, M

Channel No.

RX Frequency

TX Frequency

1

162. 05000

162. 00000

2

150. 05000

150. 00000

3

173. 95000

174. 00000

4

162. 00000

162. 00000

5

162. 20000

162. 20000

6

162. 40000

162. 40000

7~16

LCD display (Test mode)

1

1

channel No.

Signalling No.

Repair Jig (Extention Flat cable : part No.

E37-0851-05)

This cable is used for connecting the TK-270G display unit
and TX/RX unit when you test or repair the transceiver.

Caution :

You must connect TK-270G display unit when you
test or repair the transceiver.

Extention Flat cable

Display unit

TX/RX unit

Signalling

Signalling No.

RX

TX

1

None

None

2

None

100Hz square wave

3

QT 67.0Hz

QT 67.0Hz

4

QT 151.4Hz

QT 151.4Hz

5

QT 210.7Hz

QT 210.7Hz

6

QT 250.3Hz

QT 250.3Hz

7

DQT D023N

DQT D023N

8

DQT D754I

DQT D754I

9

DTMF DEC, (159D)

DTMF ENC, (159D)

10

None

DTMF tone 9

11

2 tone 321.7/928.1Hz

None

12

Single tone 1200Hz

Single tone 1200Hz

This manual is related to the following products: