beautypg.com

Realignment – Kenwood TK-270G User Manual

Page 14

background image

TK-260G/270G

14

No. Function

Choices

Display

Remarks

No. Function

Choices

Display

Remarks

4 [

]TK-270G Group Up

KEY2_25

only

Scrambler

KEY2_26

Only when scrambler is set

5 [

2

]TK-270G No Function KEY3_OFF

only

Talk Around KEY3_3

Default

Display Character KEY3_5

Home Channel KEY3_7

Channel Down KEY3_8

Channel Up KEY3_9

Keylock

KEY3_10

Lamp

KEY3_11

Selectable QT KEY3_15

M destination only

Monitor A

KEY3_17

Monitor B

KEY3_18

Monitor C

KEY3_19

Monitor D

KEY3_20

RF Power Low KEY3_21

Default

Scan

KEY3_22

Scan DEL/ADD KEY3_23

Group Down KEY3_24

Group Up

KEY3_25

Scrambler

KEY3_26

Only when scrambler is set

6 [

3

]TK-270G No Function KEY4_OFF

only

Talk Around KEY4_3

Display Character KEY4_5

Home Channel KEY4_7

Channel Down KEY4_8

Channel Up KEY4_9

Keylock

KEY4_10

Lamp

KEY4_11

Selectable QT KEY4_15

M destination only

Monitor A

KEY4_17

Monitor B

KEY4_18

Monitor C

KEY4_19

Monitor D

KEY4_20

RF Power Low KEY4_21

Default

Scan

KEY4_22

Scan DEL/ADD KEY4_23

Group Down KEY4_24

Group Up

KEY4_25

Scrambler

KEY4_26

Only when scrambler is set

7 [CH]

Channel Up/Down CH_UP/DN

Default

Group Up/Down GR_UP/DN

No Function KNOB_OFF

Optional Feature

8 Power On Tone YES/NO

PONT_YES Default:YES

9 Control Tone YES/NO

CNTT_YES Default:YES

10 Warning Tone YES/NO

WART_YES Default:YES

11 Time Out Timer OFF,15-300/15s Step TOT_60

Default:60s

12 TOT

OFF,1-10/

TOTP_PFF Cannot be set when TOT is OFF.

Pre-Alert Time 1s Step

Default:OFF

13 TOT

OFF1-60/

TOTK_OFF Cannot be set when TOT is OFF.

Rekey Time 1s Step

Default:OFF

14 TOT

OFF1-15/

TOTS_OFF Cannot be set when TOT is OFF.

Reset Time 1s Step

Default:OFF

15 Clear to Transpond YES

CTT_YES

(BCL for Transpond) NO

CTT_NO

Default

16 Battery Save ON

BATT_ON

Default

OFF

BATT_OFF

17 Signaling OR

SIG__OR

Default

AND

SIG_AND

18 Squelch Level 0-9/1 Step

SQL__5

Default;5

19 Priority

None

PRI_NONE

Default

Fixed

PRI_FIX_

Selected

PRI_SEL_

20 Lock Back 0.5-5.0/0.05 LBA_500

Default:500ms Cannot be

Time A

set when Priority = none.

21 Lock Back 0.5-5.0/0.05 LBB_2000 Default:2000ms Cannot

Time B

be set when Priority = none.

22 Revert

Selected

REV_SEL

Channel

Last Called REV_L/C_

Default

Last Used

REV_L/U_

Selected + Talk Back REV_S/T_

Priority

REV_PRI_

Priority + Talk Back REV_P/T_

23 Dropout

0-300/1s

DODT___3 Default;3s

Delay Time

24 Dwell Time 0-300/1s

DWL___3

Default;3s

DTMF

25 Digit Time 50-200/10ms DIGT__50 Default;50ms

26 Inter Digit Time 50-1000/50ms IDT___50

Default;50ms

27 First Digit Time 50-200/10ms FDT___50 Default;50ms

28 First Digit Delay 50-1000/50ms RIST_100

Default;100ms

29 Rise Time with QT 50-1000/50ms RTWQ_100 Default;100ms

30 DIAL ID

Enable

DID_ENA

Diable

DID_DIS

Default

31 No.of

12Key

NODK_12

Default

DTMF Key 16Key

NODK_16

32 DTMF Hold Time ON

DHT__ON

Default

OFF

DHT__OFF

33 Store and Send ON

SAS__ENA

OFF

SAS__CSQ

Default

REALIGNMENT