beautypg.com

Realignment – Kenwood TK-270G User Manual

Page 12

background image

TK-260G/270G

12

REALIGNMENT

Flow Chart

No. Function

Choices

Display

Remarks

3

TX frequency Step 2.5kHz-1MHz

STP_250

Same as RX frequency.

STP_1000

Blank

————

100.0000-

T.100.0000

550.0000MHz

4

TX Signaling

Same as RX signaling.

5

Option Signaling OFF

NONE____

Default

DTMF

DTMF____

2-TONE

2TONE___

6

ID

000-

___ID___

Display when an item is selected

9999999999

(about 0.5 seconds)

12345678

Display of the current setting
(If it is 8 or more digits, scroll it.)

——987

Display when a code is input
(Input it with DTMF key.)

Blank

————

[LAMP] : Data clear

7

Busy Channel NO

BCL_NO__

Default

Lockout

Type 1

BCL_1___

BCL_YES for K type

Type 2

BCL_2___

N/A for K type

8

Beat shift No

SHFT_NO_

Default

Yes

SHFT_YES

9

RF Power High Power PWR_H___

Default

Low Power PWR_L___

10 Wide/Narrow Wide

WIDE____

Narrow

NARROW__

11 Scan

DELETE

SCAN_DEL Not used for TK-260G

Delete/ADD ADD

SCAN_ADD

Default

12 Priority

No

P.CH_NO__ Not used when (Scan) Priority is not Fixed.

Channel

Yes

P.CH_YES_

13 Home Channel No

H.CH_NO__ Not used when Home Channel is

Yes

H.CH_YES_ not set in Key Assignment.

14 Compander No

COMP_NO_ Not used when Wide is selected.

Yes

COMP_YES

15 PTT ID

OFF

P.ID_OFF

Begin of TX P.ID_1
End of TX P.ID_2
Both

P.ID_3

16 Begin of

000-

_BOT_ID_

Not valid if Dial ID =Disable and

TX ID

9999999999999999

PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)

12345678

Display of the current setting
(If it is 8 or more digits, scroll it.)

——987

Display when a code is input
(Input it with DTMF key.)

Blank

————

[LAMP] : Data clear

17 END of

000-

_EOT_ID_

Not valid if Dial ID =Disable and

TX ID

9999999999999999

PTT ID=OFF, or EOT is set.
Display when an item is selected
(about 0.5 seconds)

12345678

Display of the current setting
(If it is 8 or more digits, scroll it.)

——987

Display when a code is input
(Input it with DTMF key.)

Blank

————

[LAMP] : Data clear

Self programming mode

Channel Setting Mode

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

[MON]

Channel set mode

Channel selection

OFF

OFF

OFF

QT

DQT N

DQT I

OFF

QT

DQT N

DQT I

Group selection

[MON]

RX frequency

RX signaling

[

2]

[LAMP]

[LAMP]

[LAMP]

[LAMP]

[LAMP]

[LAMP]

[LAMP]

[LAMP]

[LAMP]

Data clear

[LAMP]

Data clear

[LAMP]

Data clear

[LAMP]

[LAMP]

[ ]

[

3]

TX signaling

TX freguency

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

[

2]/[3]

option signaling

ID

Scan delete/add

Busy channel lockout

RF Power High/Low

Best Shift yes/no

Wide/Narrow

Compander yes/no

Not used when Wide is selected.

Not used when (Scan) Priority is not Fixed.

Not used when Home Channel is not set in key Assignment.

PTT ID

Priority channel

Home channel

Begin of TX ID

End of TX ID

[ ]

Not valid if Dial ID=Disable
and PTT ID=off, or EOT is set.

Not valid if Dial ID=Disable
and PTT ID=off, or BOT is set.

This manual is related to the following products: