beautypg.com

5. installation space – Sony HDW-2000 User Manual

Page 9

background image

1-3

HDW-2000/M2000/M2000P/S2000/S2000P/M2100/M2100P, DVW-2000/2000P/M2000/M2000P

MSW-2000/A2000/A2000P/M2000/M2000P/M2000E/M2000EP/M2100/M2100P/M2100E/M2100EP

15.9

454

45

105

577(Maximum traveling distance)

112

31

31

12.7

123.8

34

263.5

415.9

457.5

48

(38.5)

87

87

70.6

36.2

465

481

174

19.5

87

364

31.5

427

533

45.5

544

416(Rail-installed width)

427(Unit width)

(Mass of this unit : approx. 23 kg)

1-5. Installation Space

Moreover, an air flow that is effective in cooling the unit is
essential. If the ventilation is not enough, the unit may be
damaged because of an increase of the internal tempera-
ture.
n
This unit is air-cooled by the five fans. The operation with
the upper lid is removed affects the air cooling by the fans.
Complete the work in a short time as possible when operat-
ing the unit for inspection with the upper lid removed. If it
takes a long time, blow to the unit by an electric fan to cool
the unit.

1-5. Installation Space

When installing, the installation space must be secured in
consideration of the ventilation and service operation.
. Do not block the ventilation slots at the left side and

right side panels, and vents of the fans.

. Leave a space around the unit for ventilation.
. Leave more than 40 centimeters of space in the rear of

the unit to secure the operation area.

When the unit is installed on the desk or the like, leave at
least four centimeters of space in the left and right sides.
Leaving 40 centimeters or more of space above the unit is
recommended for service operation.

Dimensions when Rack-Mounting

n
This unit allows the operation with the detached lower control panel unit.
For details, refer to Section 1-12.

n Remove the feet when rack mounting.

Unit : mm