beautypg.com

Appendix, List of messages – Sony BRC-300P User Manual

Page 57

background image

A

ppe

ndix

List of Messages

57

Appendix

List of Messages

The following messages may appear on the screen. Take
the necessary measures shown below.

Indicators on the BRC-300/300P camera

Messages for the BRC-300/300P camera

Error messages for the BRU-300/300P Optical
Multiplex Unit

Indicator

Meaning/remedies

STANDBY lamp
flashes.

The camera stopped moving due to an
error in the pan/tilt mechanism. Reset
the pan/tilt position or turn off the power
of the camera and turn it on again.

The tally lamp
flashes.

Turn off the power of the camera, and
consult with your Sony dealer.

Message

Meaning/remedies

Please restart system You are prompted to restart the power of

the camera after you changed the setting
of "IMG-FLIP" in the SYSTEM menu or
"D-ZOOM" in the PAN TILT ZOOM
menu.
Use the POWER switch on the supplied
Remote Commander or the POWER
button on the RM-BR300 Remote
Control Unit to turn the power off, then
on. The changed setting becomes
effective.

PRESET xx OK
(xx = 1 to 6)

When you store the camera settings into
the memory (POSITION 1-6), the
message will appear for 2 seconds.

White balance active While the white balance adjustment is

automatically adjusted, the message will
blink. Wait for a while. When the
adjustment is complete, it will disappear.

White balance active
Please wait

The message will appear only when you
activate the one-push white balance
adjustment by pressing the ONE PUSH
AWB button on the RM-BR300 Remote
Control Unit.

Message

Meaning/remedies

Communication error
Please check
connection

The message will appear when the
Optical Multiplex Unit is turned on, if a
problem occurs in the connection of the
Optical Fiber Cable between the camera
and the Optical Multiplex Unit. Turn off
the power of the camera and the Optical
Multiplex Unit, check the connection of
the Optical Fiber Cable and turn the
power on again.

Option card error
Please check option
card

The message will appear when same-
type interface cards are inserted into the
two card slots on the Optical Multiplex
Unit. Turn off the power of the Optical
Multiplex Unit and remove either of the
cards.