LS 3070 Product Reference Guide: Programming

Parameter Menu Scanning

Beeper Sequence

Indication

1 Beep - short high tone

Correct entry scanned or correct menu sequence
performed.

1 Beep - lo/hi tone

Input error, incorrect bar code or CANCEL
scanned, wrong entry, incorrect bar code
programming sequence; remain in program
mode.

1 Beep - hi/lo tone

Keyboard parameter selected. Enter value using
bar code keypad.

1 Beep - hi/lo/hi/lo tone

Successful program exit with change in the
parameter setting.

Code 39 Scan And Store

Beeper Sequence

Indication

1 Beep - hi/lo tone

New Code 39 data was entered into the buffer.

3 Beeps - long high tone

Code 39 buffer is full.

1 Beep - lo/hi/lo tone

The buffer was erased, or there was an attempt to
transmit an empty buffer. When the Code 39
buffer was empty, the base station read a
command to clear or to transmit a Code 39 buffer.

2 Beeps - long high tone

Error in data transmission.

1 Beep - lo/hi tone

A successful transmission of buffered data.