beautypg.com

Ls 3070xlr technical specifications, Ls 3070xlr technical specifications -9 – Symbol Technologies LS 3070 User Manual

Page 38

background image

4-9

LS 3070 Product Reference Guide: Maintenance and Specifications

LS 3070XLR Technical Specifications

ITEM

DESCRIPTION

Power Requirements

:

Scanner

4.75 to 14 VDC; 210 mA @ 5 VDC Typical.

Base/Charger

5 VDC ± 10% @ 190 mA Typical.
12 VDC ± 10% @ 400 mA Typical.

Scan Repetition Rate

Approximately 36 (± 3) scans/sec
(bidirectional)

Start-up Time

<50 msec. from scan enable

Data Acquisition Time

<110 msec. from scan enable

Skew Tolerance

± 60° from normal

Pitch Angle

± 45° from normal

Decode Depth of Field

See

LS 3070XLR Extra Long Range on page 3-9

Minimum Element Width

0.030 in.

.762 mm

Maximum Element Width

0.1 in.

2.54 mm

Print Contrast Minimum

50% absolute dark/light reflectance
differential, measured at 675 nm.

Ambient Light Immunity

Incandescent

100 ft. candles

1076.4 lux

Fluorescent

450 ft. candles

4844 lux

Sodium Vapor

450 ft. candles

4844 lux

Mercury Vapor

450 ft. candles

4844 lux

Durability

6-ft. drop to concrete

Operating Temperature

0° to 40°C

32° to 104°F

Storage Temperature

-40° to 60°C

-40° to 140°F

Humidity

5% to 95% (non-condensing)

Height

6.3 in.

16 cm

Length

5 in.

12.7 cm

Width

2.8 in.

7.1 cm

CDRH Class

IIIA