beautypg.com

State GPG/GPV-540A User Manual

Page 17

background image

17

TwO TEMPErATUrE - ONE HEATEr HiGH TEMPErATUrE

wiTH rECirCULATiON OF SANiTiZiNG LOOP

CAUTION: IF BUILDING COLD WATER SUPPLY HAS A BACKFLOW

PREVENTER, CHECK VALVE OR WATER METER WITH CHECK VALVE,

PROVISIONS FOR THERMAL EXPANSION OF WATER IN THE HOT WATER

SYSTEM MUST BE PROVIDED.

DANGEr

TEMPErATUrE SETTiNG SHOULD NOT EXCEED SAFE TEMPErATUrE

AT FiXTUrES. SEE wATEr TEMPErATUrE CONTrOL wArNiNG ON

PAGE 23. iF HiGHEr PrEHEAT TEMPErATUrES ArE NECESSAry TO

OBTAiN ADEQUATE BOOSTEr OUTPUT, ADD AN ANTi-SCALD VALVE

FOr HOT wATEr SUPPLiED TO FiXTUrES.

*PIPE TO OPEN DRAIN

INSTALL IN ACCORDANCE WITH LOCAL CODES

NOTE 1: TOGGLE SWITCH CONTROLS 180° WATER CIRCULATION.

INSTALL ON OR CLOSE TO DISHWASHING MACHINE.

TOGGLE SWITCH MUST BE CLOSED (ON) DURING THE

RINSE OPERATION AND OPEN (OFF) WHEN DISHWASHER

IS NOT OPERATING OR WHEN ON LONG STANDBY.

NOTE 2: INSTALL LINE TEMPERATURE CONTROL IN AN UNINSULATED

TEE BEYOND THE DISHWASHING MACHINE TAKEOFF IN THE

SANITIZING LOOP. CONTROL SHOULD BE SET AT 185°F.

NOTE 3: ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW

RATE DOES NOT CAUSE UNNECESSARY TURBULENCE

IN THE TANK.

NOTE 4: IF TEMPERED WATER IS RECIRCULATED, RETURN LINE

SHOULD BE CONNECTED AT POINT “’A”.