Siemens CCIC1410 User Manual
Page 75
Configuration with the CCIC1410 Homepage
75
Siemens Building Technologies
Fire Safety & Security Products
05.2009
Event settings
In the Event settings section, click Add to open the event setting page.
In this page, you can arrange the three elements – Trigger, Schedule and Action –
to configure an event. A total of three event settings can be configured.
z
Event name:
Enter a descriptive name for the event.
–
Enable this event:
Select this option to enable this event.
–
Priority:
Select the relative importance of this event (High, Normal, and Low). Events with
higher priority setting will be executed first.
–
Detect next after …… second(s):
Enter the duration in seconds for which motion detection is to be paused after a
motion has been detected.
An event is an action initiated by a user-defined trigger source; it is the causal
arrangement of the following three elements:
Î
Trigger
Î
Event Schedule
Î
Action