2. setting of pcs-1 and hub – Sony PCS-1P User Manual
Page 75
![background image](/manuals/149901/75/background.png)
4-3
PCS-1/PCS-1P
4-2. Setting of PCS-1 and HUB
The initial setting of the PCS-1 is Auto.
In the Auto setting of the PCS-1, 10/100 can be selected automatically, however, Half/Full cannot be selected
automatically. Therefore, if the HUB is set to Full mode, a connection failure or packet loss occurs. The following table
shows an example of connection between the PCS-1 and Catalyst 2950. When the HUB is set to 100FULL or 10FULL,
change the setting of HUB or adjust the PCS-1 setting to HUB. Refer to “2-5. Service Mode” for the setting procedure of
the PCS-1.
Table of connection between PCS-1 and Catalyst 2950
PCS-1 setting
AUTO
100FULL
100HALF
10FULL
10HALF
2950 settting
AUTO
OK
Packet loss
OK
Packet loss
OK
100FULL
Packet loss
OK
Packet loss
Connection failure
Connection failure
100HALF
OK
Packet loss
OK
Connection failure
Connection failure
10FULL
Packet loss
Connection failure
Connection failure
OK
Packet loss
10HALF
OK
Connection failure
Connection failure
Packet loss
OK