Sony PCS-1P User Manual
Page 31
![background image](/manuals/149901/31/background.png)
2-1
PCS-1/PCS-1P
Section 2
Maintenance
Connect
Phone Book
Dial
Menu
Show Help
Angle Adj.
More Options
IP
LAN
Line I/F
Dial
A2
B1
B2
C1
C2
1024 Kbps
LAN Bandwidth
Dial
Save
2-1. Confirmation Procedure of Local
Terminal Operation Using Self-Loop
A self-loop is the reflected loop in ISDN unit PCS-B768.
It does not operate when ISDN unit PCS-B768 is not
connected to the communication terminal.
Operation procedure
1.
The launcher menu below is displayed when the power
switch of the communication terminal is turned on.
2.
Select a dial using
↑
,
↓
,
←
, and
→
buttons of a remote
controller and press the decide button, or press the
connect/disconnect (I/O) button of a remote controller.
The dial menu is displayed.
3.
Select the line type.
Select “Line type” using
↑
,
↓
,
←
, and
→
buttons of a
remote controller and press the decide button.
Then, select “ISDN” using
↑
and
↓
buttons and press
the decide button.
More Options
A
ISDN
Line I/F
Dial
6 B
Number of Lines
Dial
Save
4.
Select the number of lines used.
Select “Number of lines used” using
↑
,
↓
,
←
, and
→
buttons of a remote controller and press the decide
button.
Then, select “12B” using
↑
and
↓
buttons and press
the decide button.
5.
Select column A using
↑
,
↓
,
←
, and
→
buttons of a
remote controller and press the decide button.
Enter
* in column A from the remote controller two
times
6.
Select “Dial” using
↑
,
↓
,
←
, and
→
buttons of a
remote controller and press the decide button, or press
the connect/disconnect (I/O) button of a remote
controller.
A self-loopback is started and “Outgoing” is displayed
on the monitor screen. “Start meeting” is displayed
when the loopback is completed. In this case, confirm
that an image and voice are looped.