Coolant reservoir, Checking coolant level – Southbend South Bend SB1027 User Manual
Page 50
-48-
For Machines Mfg. Since 8/09
Model SB1027
M A I N T E N A N C E
Coolant Reservoir
A small amount of coolant is lost during normal
operation. Check the coolant reservoir regularly
and fill it if necessary. We recommend changing
the coolant every three months or sooner if it
develops an unpleasant odor.
The coolant reservoir holds approximately five
gallons (19 liters) of fluid.
Checking Coolant Level
Tools Needed
Qty
Hex Wrench 3mm .................................................1
Piece of Wire ..........................................................1
Figure 56. Locations of the coolant drain screens.
Drain
Screens
Running the coolant pump without adequate
coolant in the reservoir may permanently
damage the coolant pump. This action is
considered abusive and is not covered by the
warranty.
3. If the level of coolant in the reservoir is less
than 2", add more fluid through the screen to
fill the tank.
BIOLOGICAL & POISON
HAZARD!
Use the correct personal
protection equipment
when handling cutting
fluid. Follow federal, state,
and fluid manufacturer
requirements for proper
disposal.
To check the coolant level:
1. DISCONNECT MILL FROM POWER!
2. Clean away debris and grime from the
coolant drain screens on the base of the mill
(see Figure 56), then insert a clean and dry
piece of wire through one of the screens to
check the level of the coolant.