O P E R A T I O N

Figure 30. Parallel block positioned for the Y-axis

measurement (top view).

Parallel Block

Indicator

Spindle

Table (Top View)

10. Rotate the spindle so that the indicator point

rests on the parallel bar, as illustrated in

Figure 30, then zero the dial.

11. Rotate the spindle so that the indicator point

rests on the other end of the bar in the same

manner, then read the dial.

— If the indicator dial still reads zero or

is within the acceptable variance, the

spindle is precisely perpendicular to the

table in both the X- and Y-axes and the

tramming procedure is complete.

— If the indicator dial has moved from zero

beyond the acceptable variance, you will

need to compensate for that amount by

tilting the head forward or back. Repeat

Steps 9–10 until you are satisfied with

the spindle axis alignment along the table

Y-axis.

Note: Keep one of the tilt lock bolts snug so

that the head does not move loosely while

you adjust it small amounts.

12. Re-tighten the tilt lock bolts.

Note: It is a good idea to repeat Steps 9-10 again

in case the head moved slightly during the

process of re-tightening the lock bolts.

9. Place the parallel block directly under the

spindle and across the width of the table, as

illustrated in Figure 30.

Note: Generally, the goal in the next steps is to

get the difference of the indicator readings

between the end of the parallel bar down to

0.0005". However, the acceptable variance

will depend on the requirements for your

operation.

6. Rotate the spindle by hand so that the

indicator point rests on one end of the

parallel block, as illustrated in Figure 29,

then zero the dial.

7. Rotate the spindle so that the indicator point

rests in the same manner on the other end of

the block, then read the dial.

— If the indicator dial still reads zero or is

within the acceptable variance, continue

on with Step 8.

— If the indicator dial has moved from zero

beyond the acceptable variance, you will

need to compensate for that amount by

rotating the head left or right. Repeat

Steps 5–6 until you are satisfied with the

spindle axis alignment along the table

X-axis.

Note: Keep one of the rotation lock bolts

snug so that the head does not move

loosely while you adjust it small amounts.

8. Re-tighten the rotation lock bolts.

Note: It is a good idea to repeat Steps 5-6 again

in case the head moved slightly during the

process of re-tightening the lock bolts.