CAMERA Settings

B/W Mode Settings

1

Click the [DETAIL] button in the
DAY/NIGHT field and set MODE to “B/W”.

2

Set “AGC Gain” to “+12 dB” (example).

3

Click the [SET] button.
This completes the B/W mode settings.
Monitoring will switch to black & white
according to the set conditions.

TIMER Mode Settings

Example: To set monitoring to black & white

between 20:00 p.m. and 4.00 a.m.

1

Click the [DETAIL] button in the
DAY/NIGHT field and set MODE to
“TIMER”.

2

Set “AGC Gain” to “+12 dB” (example).

3

Set “ALARM OUT” to “NO” (example).
A signal can be output from the ALARM OUT
terminal when monitoring switches to black &
white. (An IR lamp can be connected so that
it illuminates at such times.)

4

Set “BURST” to “OFF” (example).

5

Change the TIMER ON setting to “20:00”
and the OFF setting to “04:00”.

6

Click the [SET] button.
This completes the TIMER mode settings.
Monitoring will switch from color to black &
white during the set time period. At other
times, monitoring will be in color.