The watch-clock command, The watch-net and watch-net-all commands – Sun Microsystems SUN FIRE 280R User Manual
Page 200
172
Sun Fire 280R Server Owner’s Guide • January 2001
The
watch-clock
Command
The
watch-clock
command displays a number that increments once per second.
During normal operation, the seconds counter repeatedly increments from 0 to 59.
The following shows an example snapshot of output from the
watch-clock
command.
The
watch-net
and
watch-net-all
Commands
The
watch-net
and
watch-net-all
commands monitor Ethernet packets on the
Ethernet interfaces connected to the system. Good packets received by the system
are indicated by a period (.). Errors such as the framing error and the cyclic
redundancy check (CRC) error are indicated with an X and an associated error
description.
The following examples show
watch-net
and the
watch-net-all
command
output.
{0} ok watch-clock
Watching the ‘seconds’ register of the real time clock chip.
It should be ‘ticking’ once a second.
Type any key to stop.
4
{0} ok watch-net
gme register test --- succeeded.
Internal loopback test -- succeeded.
Transceiver check -- Using Onboard Transceiver - Link Up. up
Using Onboard Transceiver - Link Up.
Looking for Ethernet Packets.
‘.’ is a Good Packet. ‘X’ is a Bad Packet.
Type any key to stop.................................
{0} ok watch-net-all
/pci@8,700000/network@5,1
gme register test --- succeeded.
Internal loopback test -- succeeded.
Link is -- Using Onboard Transceiver - Link Up Up.