LOCATIONS OF CONTROLS AND INDICATORS

Back Panel (SRT-4040DC only)

1

Battery compartment

2

ALARM IN (alarm trigger input) terminal
1 SHOT IN (single image recording trigger input)
terminal

3

CONTROL IN terminal

4

SERIES IN (series recording trigger input) terminal

5

EXT TIMER IN (external timer trigger input) terminal
ALARM REST IN (alarm recording reset input)
terminal

6

COM terminal

7

WARNING OUT (warning output) terminal

œ

Signals are output when an alarm, clog detection,
video loss, non-recording or mechanism problem
occurs.

8

CONTROL OUT terminal

9

TAPE END OUT (tape end output) terminal

F

TIMER OUT (timer recording output) terminal

G

SW OUT (switch output) terminal

H

VIDEO IN (video input) jack

I

VIDEO OUT (video output) jack

J

AUDIO OUT (audio output) jack

K

AUDIO IN (audio input) jack

L

REMOTE (remote control input) jack

M

DC12-24V IN “+” input terminal

N

Do not use

O

DC12-24V IN “–” input terminal

P

Fuse cover

1

RS-485 interface board (sold separately)

A

SHORT FOR TERMINATION terminal

B

SHORT FOR TERMINATION terminal

C

Do not use

D

Do not use

E

COM terminal

F

RS485 A terminal

G

RS485 B terminal

H

COM terminal

I

RS485 A terminal

J

RS485 B terminal

NOTES:

œ

The above illustration shows the unit when the
RS-485 interface board is installed. If no RS-485
interface board is installed, connectors and switches

A

through to

J

do not appear.

œ

The terminal may be damaged by a torque of 0.49
N.m (5kg.cm) or more and by using screwdriver with a
tip with a diameter of 6 mm or more.

œ

The

3

,

4

,

8

and

F

terminals can be used to select

the input and output signals. (Refer to “SELECTING
INPUT AND OUTPUT TERMINALS” on page 38.)

œ

If using the

3

and

8

terminals, multiple VCRs can be

operated by operating a single VCR. (Refer to
“SYNCHRONIZATION CONTROL” on page 40.)

œ

A fuse has always to be replaced by a fuse with the
same ratings (250 V, 5 A)

AUDIO

VIDEO

OUT

OUT

IN

IN

REMOTE

OPEN COLLECTOR

ALARM(1 SHOT)IN

SERIES IN 3

COM

CONTROL OUT 3

CONTROL IN 3

WARNING OUT 1

EXT TIMER

(ALARM RESET) IN

TAPE END OUT 2 SW OUT

TIMER OUT 3

1=500mA(Max.)

2= 50mA(Max.)

3=SEE MANUAL

PUSH
OPEN

1

L

I

J

K

H

DC 12-24V IN

M

N

O

P

ALARM(1 SHOT)IN

SERIES IN 3

SHORT FOR

TERMINATION.

COM

COM

COM

RS485 A

RS485 B

RS485 B

RS485 A

CONTROL OUT 3

CONTROL IN 3

WARNING OUT 1

EXT TIMER

(ALARM RESET) IN

TAPE END OUT 2 SW OUT

TIMER OUT 3

3

B

G

J

F

I

8

G

6

E

4

C

2

A

1

9

H

7

F

5

D

With the RS-485 interface board

NB4QR/NA (SRT-4040 GB) Tue. Sept., 10/2002

8

English