OUTPUT TERMINALS

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT
terminal.

This terminal is usually connected to the switch input
(SW IN) of devices like a camera switcher unit, or a quad
compressor.

SW OUT Terminal Output Setting

1

Press the MENU button to display the MAIN MENU.

2

Press the

l

(or

j

) button to select the

“2.DISPLAY/SW OUT SET” line, then press the
ENTER button.

ø

The (DISPLAY/SW OUT SET) menu appears.

@@@@SET@UP

DATE@@@@@@@@@@@@@Y

TIME@@@@@@@@@@@@@Y

SPEED@@@@@@@@@@@@Y

ALARM@COUNT@@@@@@Y

TIMING@@@@@@@@@@@FIELD

FIELD@@@@@@@@@@@@1

8H@MODE@@@@@@@@@@Y

3

Press the

l

(or

j

) button until the “TIMING” setting

is highlighted, then press the ENTER button.

4

Press the

l

(or

j

) button to select the desired

output timing, then press the ENTER button.

FIELD. . . . . . 1 pulse is output after each set

number of fields.

FRAME . . . . 1 pulse is output after each set

number of frames.

5

Press the ENTER button.

6

Press the

l

(or

j

) button to select the desired pulse

signal interval (1, 2, 3, 4, 5, 10, 30 or 60), then press
the ENTER button.

œ

If “TIMING” is set to FRAME (see step

4

),

“FRAME” will be indicated instead of “FIELD”.

7

Press the ENTER button.

8

Press the

l

(or

j

) button to select the desired “8H

MODE (or 6H MODE)” mode, then press the ENTER
button.

œ

If the “TAPE” in the (GENERAL SET) menu is set
to “T-120”, “6H” will be indicated instead of “8H”.

Y. . . . . . . . . . When recording in 8-hour (or

6-hour) mode, a pulse signal is
output.

N . . . . . . . . . When recording in 8-hour (or

6-hour) mode, a pulse signal is
not output.

9

Press the MENU EXIT button.

5V (H)

0V (L)

(Output impedance: 5.7 k

)

FIELD: 16.7 msec.
FRAME: 5 msec.

NB4QR/NA (SRT-4040 GB) Tue. Sept., 10/2002

English

45