2.2 Mechanical Installation
WARNING
THIS EQUIPMENT MUST BE EARTHED.
To guarantee the safe operation of the equipment it must be installed and commissioned properly
by qualified personnel in compliance with the warnings laid down in these operating instructions.
Take particular note of the general and regional installation and safety regulations regarding work
on dangerous voltage installations (e.g. VDE), as well as the relevant regulations regarding the
correct use of tools and personal protective gear.
The mains input and motor terminals can carry dangerous voltages even if the inverter is
inoperative. Use insulated screwdrivers only on these terminal blocks.
Environmental Requirements
Hazard
Notes
Ideal Installation
Temperature
Altitude
Shock
Vibration
Electro-Magnetic
Radiation
Atmospheric
Pollution
Water
Overheating
Min. = 0
°
C
Max. = 50
°
C
If the Inverter is to be installed at an altitude >
1000 m, derating will be required.(Refer to DA 64
Catalogue).
Do not drop the inverter or expose to sudden
shock.
Do not install the inverter in an area where it is
likely to be exposed to constant vibration.
Do not install the inverter near sources of
electro-magnetic radiation.
Do not install the inverter in an environment
which contains atmospheric pollutants such as
dust, corrosive gases, etc.
Take care to site the inverter away from potential
water hazards. e.g. Do not install the inverter
beneath pipes that are subject to condensation.
Ensure that the inverter’s air vents are not
obstructed.
Make sure that there is an adequate air-flow
through the cabinet, as follows:
1. Using the formula below, calculate the airflow
required.
Air-flow (m
3
/ hr) = (Dissipated Watts /
∆
T) x 3.1
2. Install cabinet cooling fan(s) if necessary,
Note:
Typical dissipation (Watts) = 3% of inverter
rating.
∆
T = Allowable temperature rise within cabinet
in °C.
3.1 = Specific heat of air at sea level.
160 mm
100 mm