Model 5100-xx-it toxic gas sensor module – Sierra Monitor Corporation 5100-06-IT User Manual
Page 36

Model 5100-XX-IT Toxic Gas Sensor Module
Page: 32
Cross Sensitivity Data:
5100-04-IT Carbon Monoxide
Gas
Conc.
Response
HS
15 PPM
~38 PPM
SO
2
5 PPM
~3 PPM
NO
35 PPM
~10 PPM
NO
2
5 PPM
~-3 PPM
H
2
100 PPM
<60 PPM
C
2
H
4
100 PPM
<100 PPM
HCN
10 PPM
~5 PPM
HCl
5 PPM
0 PPM
5100-12-IT Nitrogen Dioxide
Gas
Conc.
Response
CO
300 PPM
0 PPM
H
2
S
15 PPM
-1.5 to 0 PPM
SO
2
5 PPM
-0.05 to 0 PPM
NO
35 PPM
0 PPM
Cl
2
1 PPM
~1 PPM
H
2
100 PPM
0 PPM
HCN
10 PPM
0 PPM
HCl
5 PPM
0 PPM
C
2
H
4
100 PPM
0 PPM
5100-05-IT Hydrogen Sulfide
Gas
Conc.
Response
CO
400 PPM
<.1 PPM
SO
2
20 PPM
<10 PPM
NO
50 PPM
<3 PPM
NO
2
10 PPM
<-30 PPM
Cl
2
10 PPM
<-25 PPM
H
2
400 PPM
1 PPM
C
2
H
4
400 PPM
<0.1 PPM
NH
3
20 PPM
<0.1 PPM
5100-21-IT Hydrogen Chloride
Gas
Conc.
Response
CO
300 PPM
<3 PPM
H
2
S
15 PPM
27 to 45 PPM
SO
2
5 PPM
1.5 to 3.5 PPM
NO
35 PPM
0 PPM
NO
2
5 PPM
0.5 to 1 PPM
Cl
2
1
PPM
-0.05 to 0.1
PPM
H
2
100 PPM
<0.5 PPM
HCN
10 PPM
<0.3 PPM
5100-06-IT Chlorine &
5100-08-IT Chlorine Dioxide
Gas
Conc.
Response
CO
300 PPM
0 PPM
H
2
S
15 PPM
0 to -3.38 PPM
SO
2
5 PPM
-0.05 PPM
NO
35 PPM
0 PPM
NO
2
5 PPM
~5 PPM
H
2
100 PPM
0 PPM
C
2
H
4
100 PPM
0 PPM
HCN
10 PPM
0 PPM
HCl
5 PPM
0 PPM
ClO
2
3 PPM
10 PPM
5100-25-IT Ammonia
Gas
Conc.
Response
CO
1000 PPM
0 PPM
SO
2
15 PPM
>40 PPM
NO
100 PPM
0 PPM
NO
2
60 PPM
0 PPM
H
2
4% 0
PPM
CH
4
4%
0
PPM
HCN
10 PPM
75 PPM
H
2
S
3 PPM
75 PPM
5100-26-IT Hydrogen Fluoride
Gas
Conc.
Response
Cl
2
5 PPM
8 PPM
HCl
5 PPM
9 PPM
NH
3
75 PPM
0 PPM
SiH
4
15 PPM
0 PPM
CO
1000 PPM
0 PPM
SO
2
5 PPM
9 PPM
NO
100 PPM
0 PPM
NO
2
15 PPM
2 PPM
H
2
4% 0
PPM
H
2
S
30 PPM
0 PPM
5100-10-IT Sulfur Dioxide
Gas
Conc.
Response
H
2
S
15 PPM
0 PPM
NO
35 PPM
-7 to 0 PPM
NO
2
5 PPM
-5 PPM
Cl
2
5 PPM
-1.5 to 0 PPM
NO
2
5 PPM
~5 PPM
H
2
100 PPM
0 PPM
HCN
10 PPM
<5 PPM
HCl
5 PPM
0 PPM
C
2
H
4
100 PPM
0 PPM