beautypg.com

SMC Networks EX500 User Manual

Page 8

background image

EX500 Serial System

EX## - OME0008

- 7 -

3. Specification and Product numbers

3 -1. General specification of EX500 series

Item

Specification

Enclosure

IP65

Standard

UL,CSA,CE

Withstand voltage

1500V AC 1min. ( between PE - external terminal package )

Insulation resistance

2MΩor more
( 500VDC meg. between PE - external terminal package )

Momentary power failure

1m sec. or less

Ambient temperature

+5℃ to +45℃

Ambient humidity

35% to 85%RH ( without condensation )

Preservation temperature

- 25℃ to 70℃

Vibration proof

10Hz to 57Hz 0.35mm ( constant amplitude )
57Hz to 150Hz 5G ( constant speed )
2 hours per each direction of ±X,Y and Z

Shock resistance

Peak value : 15G
3 times per each direction of ±X,Y and Z

Applicable altitude

Less than 1000m above sea

・・

EMC Directive ( 89 / 336 / EEC )

EN50081-2 / 1993, EN55011 / 1998 +A1 : 1999, EN50082-2 / 1995, EN61000-6-2 / 1999

Electromagnetic Emission

Item

Test Procedure

Specification

Criterion

Radiated Electric Field
Strength

EN55011 : 1998 +A1
: 1999

30MHz to 230MHz, 230MHz to 1GHz
( Distance : 10m )

Group 1

Class A

Electromagnetic Susceptibility ( Immunity )

Item

Test Procedure

Specification

Criterion

ESD

EN61000-4-2 : 1995 /
A1 : 1998

±

4kV contact

±

8kV air discharge

B

RS :
Radiated Susceptibility
( amplitude modulated)

EN61000-4-3 : 1996 /
A1 : 1998

80MHz to 1000MHz
10V / m ( 1kHz AM 80% )

A

RS :
Radiated Susceptibility
( pulse modulated )

ENV50204 : 1995

900±5MHz
10V / m
( 200Hz Pulse Mod. Duty 50% )

A

CS :
Conductive
Susceptibility
( amplitude modulated)

EN61000-4-6 : 1996

0.15MHz to 80 MHz
10V ( 1kHz AM 80% )

A

EFT / Burst,
DC power lines

EN61000-4-4 : 1995

±

2kV

( 5 / 50ns, 5kHz )

B

EFT / Burst,
control lines

EN61000-4-4 : 1995

±

2kV

( 5 / 50ns, 5kHz )

B

Surge,
interface lines

EN61000-4-5 : 1995

±

1kV ( Common )

B